Start Date: ,
End Date: ,
Click here to access the article.
Extracorporeal circulation (ECC) in cardiac surgery is performed under systemic heparinization. Adequacy of heparin therapy and anticoagulation during ECC is assessed by activated clotting time (ACT), although there are concerns regarding the reliability of this measure. The ACT can be affected by factors other than heparin anticoagulation. A novel factor that should be considered is the influence of a COVID-19 infection. More than half of the hospitalized COVID-19 patients develop coagulation abnormalities with dysregulated coagulation test results. Patients recently recovered from COVID-19 may still demonstrate some forms of coagulation disorder affecting the ACT. This case describes an inaccurate point-of-care ACT testing in a patient with previous COVID-19 infection undergoing cardiac surgery with ECC and the alternative coagulation testing performed.